| Product model | Apollo 50K-T0 / Apollo 60K-T0 |
| Max. efficiency | 0.99 |
| European weighted efficiency | 0.985 |
| Max. input voltage | 1100 V |
| Max. PV config | 1.5 |
| Rated input voltage | 620 V |
| Max. input current | 130A (39A/39A/26A/26A) / 156A (39A/39A/39A/39A) |
| Max. short-circuit current | 150A (45A/45A/30A/30A) / 180A (45A/45A/45A/45A) |
| Start-up input voltage | 250 V |
| MPPT operating voltage range | 200V-1000V |
| Max. number of MPPT strings | 10 (3/3/2/2) / 12 (3/3/3/3) |
| Number of MPPTs | 4 |
| Rated AC active power | 50,000 W / 60,000 W |
| Max. AC apparent power | 55,000 VA / 66,000 VA |
| Max. AC active power (PF=1) | 55,000 W / 66,000 W |
| Max. AC output current | 3 * 76A / 3 * 92A |
| Rated AC voltage | 380V/400V, 3W+N+PE |
| AC voltage range | 277V-520V (adjustable) |
| Rated grid frequency | 50 Hz / 60 Hz |
| Grid frequency range | 45Hz-55Hz / 55Hz-65Hz (adjustable) |
| Total harmonic distortion (THDi) | <3% (at rated power) |
| DC injection | <0.5% In |
| Power factor | >0.99 at rated power (adjustable 0.8 lead - 0.8 lag) |
| DC switch / Anti-islanding | Supported |
| AC overcurrent protection / AC short circuit protection | Supported |
| DC reverse polarity protection | Supported |
| Surge arrester | DC Class II / AC Class II |
| Insulation impedance detection / Leakage current protection | Supported |
| Topology | Transformerless |
| Protection degree | IP65 |
| Night self-consumption | <1 W |
| Cooling | Fan cooling |
| Operating temperature range | -25℃ - 60℃ |
| Allowed relative humidity range | 0 - 100% |
| Max. operating altitude | 4000 m |
| Typical noise level | <62 dB |
| Dimensions (W*H*D) | 855 mm * 555 mm * 275 mm |
| Weight | 73 Kg / 74 Kg |
| Display method | Wireless & APP+LED, LCD (optional) |
| Communication interfaces | RS485, WiFi / GPRS / 4G / LAN (optional) |
| Safety certification | IEC62109-1, IEC62109-2 |
| Grid codes | VDE-AR-N 4105, EN 50549-1, CEI 0-21, UNE 206006/206007-1, UNE 217001, IEC 61727/62116 |
| Warranty | 5 years |